All Categories
enEN
CPAP Machine

Home / Products / Operation Room & ICU / CPAP Machine

CWH-3010 ICU Ventilator
CWH-3010 ICU Ventilator

CWH-3010 ICU Ventilator

Product Brochure:DOWNLOAD

  • Introduction
Introduction

Features

•12.1 inch touch screen with desirable color schemes

•The simplest interface boots a precise control and convenient operation

•Applied for adult,pediatric and infant

•Multi-mode ventilation function (VCV, SI MV,SIMV/PSV.PSV, PCV, APNEA.CPAP, BIPAP.Manual, SIGH)

•Applied with Invasive ventilation and Non-invasive ventilation

•Advanced air compressor for air input

•Self testing and calibration function

•Design of intelligent flashing alarm indicator(Priority alarm, secondary alarm)

•Auto-wash for exhaust valve

•Assistant Nebulization treatment , High flow oxygen Therapy

图片5

Auxilary suction function

Technique Specifications
Physical Specifications
Dimensions:45*55*140cm
Weight:65kg
Casters:Front wheels with lock
Screen:12.1 inch touch screen
DisplayColour LCD
Display graphicsWaveforms of P-T, F-T, V-T
LoopsP-V, F-V, F-P
Pipeline Supply
Gas configuration02, Air
Pipeline input range280-600kPa
Air Compressor Specifications
PowerAC 220V±10%, 50Hz±2%
Output pressure0.4±0.1MPa
NoiseW50dB
Battery Power
Battery TypeLead-acid 12V, 4Ah
Run-timeTypical 180 mins+
Ventilator Specifications
Modes of Ventilation
VCVVolume control ventilation
APNEAAPNEA
SIMVSynchronized Intermittent Mandatory Ventilation
SIMV/PSVSIMV/Pressure support
MANUALManual
CPAPContinuous Positive Airway Pressure
PSVPressure Support Ventilation
PCVPressure Control Ventilation
NIVNon-invasive ventilation
BIPAPBIPAP
SIGHSIGH
ARPV(optional)
Ventilator Parameter
Tidal Volume range20-2000ml (10ml optional)
Pressure range5-80 cmhhO
Rispriation Rate Range1-100bpm (1-40bpm under SIMV)
l:E Range4:1-1:8
Oxygen concentration21%-100%
Ptrigger Range・20・0cmH2。
Apnea Ti Range0-6s
PEEP
TypeIntegrated, Electronic control
Range(MOcmFhO
Alarm Limits
VisualNo tidal volume, MV,Paw, FiO2 limitation。?,
Air failure, AC power failure, backup low
AudioNo tidal volume, MV,Paw, FiO2 limitation
Pre-setting Functions
LanguageEnglish
CalibrationAUTOMATIC
Optional
Auxiliary Suction function
O2 remedy
Communication portRS-232,VGA,Ethernet, USB (Optional)
Environmental Conditions
Operating Temp5 C ~40 C
Storage Temp-10 C~+40 C
Humidity《80%
Atmosphere pressure960 hPa-1040 hPa